Kev saib xyuas txhua hnub ntawm ECG saib!

ECG saib yog cov cuab yeej tsis siv neeg thiab ntse, uas yog siv los saib xyuas lub cev tsis zoo ntawm cov neeg mob thiab ua lub luag haujlwm tseem ceeb hauv kev ua kom muaj kev nyab xeeb ntawm lub neej ntawm cov neeg mob hnyav. ECG saib kuj yog cov cuab yeej siv hluav taws xob siv hauv chav haujlwm thiab muaj tus lej loj tshaj plaws hauv tsev kho mob. Cov neeg ua haujlwm kho mob yuav tsum tau xyuam xim rau kev siv txhua hnub, kev saib xyuas thiab tshuaj tua kab mob kom lub tshuab ua haujlwm tau zoo tshaj plaws.
Cov kev ceev faj:
01. Plua plav
Ntau yam khoom siv kho qhov muag hauv qhov ntsuas, qee qhov hloov pauv, hluav taws xob poob siab, thiab lwm yam, yuav tsum tau ceev kom huv si tsis tu ncua. Tsis tas li ntawd, txij li thaum NBP cuff yog khi rau tus neeg mob ntev, nws yuav tsum tau ntxuav tsis tu ncua kom tshem tawm cov ntxhiab ntawm lub cuff, tshwj xeeb tshaj yog rau qee cov neeg mob los ntshav thiab ntuav.
02. Moisture -pov thawj
Cov khoom siv optoelectronic thiab cov khoom siv hluav taws xob hauv cov cuab yeej yog qhov ua rau mildew thiab kev puas tsuaj tom qab raug cuam tshuam los ntawm cov dej noo. Yog li ntawd, nws yog ib qho tsim nyog yuav tau pib lub tshuab tsis tu ncua los xyuas thiab hloov cov desiccant hauv lub sijhawm. Qhov no yeej zoo ib yam li cov khoom siv hauv tsev hauv tsev. Thaum tsis siv sijhawm ntev, nws yuav tsum tau siv lub zog tsis tu ncua kom tshem tawm cov dej noo thiab ua tiav lub hom phiaj ntawm kev ya raws - pov thawj. Thaum lub caij Huangmei, huab cua yog qhov ntub tshaj plaws, yog li koj yuav tsum tau ceev faj ntxiv.
03, tiv thaiv tshav kub
High -cov cuab yeej hluav taws xob precision yog qhov muag heev, thiab qhov kub thiab txias siab dhau los yog qis dhau yuav cuam tshuam rau nws txoj haujlwm ib txwm muaj. Cov saib xyuas feem ntau xav tau qhov chaw ua haujlwm tsim nyog thiab khaws cia thiab qhov ntsuas kub me me, yog li nws yog qhov zoo tshaj plaws los teeb tsa lub ntsuas kub. Feem ntau, nws yog qhov tsim nyog los khaws qhov kub ntawm 20 degree 25 degree. Tsis tas li ntawd, nws yuav tsum tau kom deb ntawm qhov chaw kub xws li cov khoom siv kho mob infrared, thiab tsis txhob raug tshav ntuj ncaj qha.
04. Anti-kev co
Kev vibration yuav tsis tsuas yog cuam tshuam rau kev ua tau zoo thiab ntsuas cov txiaj ntsig ntawm tus saib, tab sis kuj ua rau muaj kev puas tsuaj rau qee qhov kev ua kom raug, yog li nws yuav tsum tau muab cov cuab yeej tso rau ntawm qhov chaw ua haujlwm lossis kev vibration - damping rooj deb ntawm qhov chaw vibration.
05. Kev tiv thaiv -corrosion
Thaum siv thiab khaws cov cuab yeej, tsis txhob sib cuag nrog ib puag ncig nrog corrosive gases thiab kua xws li acid thiab alkali, thiaj li tiv thaiv cov khoom los ntawm kev puas tsuaj los ntawm yaig.
Xyuas ua ntej siv
♥The environment and power supply meet the requirements.
♥The case of the monitor is clean and free of smudges.
♥The shell, buttons, knobs, interfaces and accessories have no mechanical damage.
♥The power cord has no abrasion and good insulation performance.
♥The ground wire is connected correctly.
♥ Use only specified accessories such as electrodes, sensors and probes.
♥ The clock of the monitor is correct.
♥ Sound alarm and light alarm function normally.
♥ The recorder works normally and the recording paper meets the specified requirements.
♥ Check the performance of the battery.
♥Various monitoring functions of the system are in good working condition.
ntxuav thiab tua kab mob
01. Cov kauj ruam tu:
Turn off the monitor and disconnect the AC power → Clean the outside of the main unit → Clean the display screen → Clean the cables and sensors → Wipe the cleaned part with a dry cloth or air dry → If there is contamination by patient secretions, use chlorine Wipe with disinfectant, then wipe with water to dry → place the device in a ventilated and cool environment to air dry.
02. Kev tu sab nraud ntawm tus tswv tsev:
Ib daim ntaub huv, mos, daim txhuam cev lossis paj rwb pob yuav tsum tau siv los nqus cov khoom tsis zoo -txhaj tshuaj ntxuav, wring kom zoo thiab so maj mam. Cov tshuaj ntxuav tu uas xaiv tau: diluted soapy dej, diluted ammonia, sodium hypochlorite (bleaching hmoov rau ntxuav), los yog formaldehyde (3537 feem pua), hydrogen peroxide (3 feem pua), 70 feem pua ethanol, 70 feem pua isopropanol. So qhuav nrog ib daim ntaub huv huv.
03. Tso saib tu txoj kev:
So nrog 75 feem pua coj paj rwb pob txhua lub lim tiam. So cov zaub nrog 10% tshuaj dawb los yog dilute cov dej xab npum. So qhuav nrog ib daim ntaub huv huv.
04. Yuav ua li cas ntxuav lub cable:
♥Please wipe the outer surface of the cable with 75 percent alcohol, be careful not to let the liquid flow into the cable connector. Also do not immerse in liquids.
♥ If there is any residue such as tape on the wire, it should be wiped with tape remover and then disinfected.
♥ Air dry or clean with a clean, dry cloth.
♥The wires that are too long can be bent into larger circles and tied up and fixed for ease of use. Disposable parts must be discarded and not ready for reuse after washing.
♥During backup, each lead wire and connecting tube should be bundled and fixed separately, and placed in a plastic bag or cloth bag to keep it clean and tidy, so that it can be used again.
05. Txoj kev ntxuav cov ntshav oxygen sojntsuam:
♥ Remove the sensor from the patient and from the monitor.
♥Please wipe the sensor with 75 percent alcohol, then dry it with a dry cloth. (It can also be used to clean the light-emitting and receiving parts.) Be careful not to let liquid flow into the cable socket. Also do not immerse in liquids.
♥ Clean the rest of the same cable.
06. Txoj kev ntxuav ntawm cuff:
♥The cuff cannot be dry cleaned, but it can be machine washed or hand washed, and hand washing can prolong the life of use. Before washing, the rubber bag should be removed. After washing, wait for the sleeve to dry before repacking the rubber bag.
♥The sleeve can be sterilized by conventional methods, such as: autoclaving, gas or radiation sterilization, sterilization by immersion in decontamination solution. (Now replace the cuff twice a week and send it to the supply room for disinfection).
♥(For special infection treatment) Soak the cuff in 0.5g/L chlorine-containing disinfectant (or 75 percent alcohol) for 30 minutes, then rinse it with clean water and dry it in the air for later use.
kev saib xyuas
♥The monitor should be placed in a ventilated and dry place.
♥Connect the purification power supply to maintain the voltage (220±22)V, reduce the use with high-power electrical appliances.
♥ Before cleaning and sterilizing the monitor, turn off the monitor and disconnect the AC power supply at the same time.
♥ When arranging accessories, do not fold the lines, but wrap them in a circle to avoid breaking.
♥Do not perform high temperature, high pressure and immersion disinfection on the ECG monitor and accessories, and avoid contact with corrosive gases and liquids such as acid and alkali. Never immerse any part of the system in liquid. If liquid is accidentally spilled on the monitor, it should be wiped with a dry cloth immediately. Do not let liquid flow into the monitor. Personnel overhaul.
♥Avoid frequent switching on and off of the instrument. When the patient only suspends the instrument for a long time, just remove the monitoring electrode buckle, and it is not necessary to turn off the instrument. If you see signs of deterioration or damage to the cable, replace the cable and do not use it for patient monitoring.
♥Be careful not to fold the hose connecting the cuff, it is easy to be damaged when folded for a long time.
♥ When the printed ECG bands are too light or inconsistent in shades, clean the surface of the print head with a cotton ball dipped in alcohol to remove the remaining paper scraps.
♥The staff wash their hands and trim their nails before operation, so as not to damage the touch buttons or the screen.
♥At least 5CM space should be reserved around the monitoring instrument in use to ensure the circulation of air and achieve good heat dissipation effect. The monitor in the standby state should be placed in a ventilated and dry place to avoid moisture, and should be charged regularly, usually once a week, and checked, cleaned and maintained; it should be kept by a special person.
♥ Regularly conduct stability tests on the monitoring indicators of the monitor and keep the qualified records.
♥When the monitor fails, you should contact the maintenance personnel in time for maintenance and keep the maintenance records.
♥Equipped with operating procedures and troubleshooting procedures for various types of monitors, which are convenient for medical staff to use.
♥Have records of monitor usage, maintenance, repair and disinfection.